Loading...
HomeMy WebLinkAboutAGREEMENT BETWEEN AUGUSTA UTILITIES DEPARTMENT AND INDUSTRIAL SCIENTIFIC FOR CONFINED SPACE MONITORING SERVICES Agmt of Amendment Renewal/Equipment Change(Rev.07-06-2011) City of Augusta Case#20180319-1411878 Agreement of Amendment This Agreement of Amendment is made effective as of April 4, 2018, by and between INDUSTRIAL SCIENTIFIC CORPORATION, a Pennsylvania corporation ("Company"), and CITY OF AUGUSTA, a Georgia municipality corporation(the"Customer" and, along with Company, the "Parties,"provided the Parties may be individually referred to as a"Party"). Company and Customer entered into an iNet Usage Agreement dated March 9,2014(the"Agreement"),under which Company agreed to provide its iNet gas detection services to Customer for a Term that commenced May 9, 2014,and expired on May 8,2018,and; Company and Customer desire to extend the Term of the Agreement and to revise the Subscription Fees and the Equipment covered by the Agreement as detailed below. Company and Customer hereby agree to amend the Agreement as follows: 1. Except where the context otherwise requires, words and expressions defined in the Agreement shall have the same meanings when used herein;references to sections are to sections of the Agreement. 2. Section 1, "Subscription," is amended to provide that the Term of the Agreement will be extended for a period of forty-eight(48)months, such that the Term shall now commence September 9,2018 and expire on September 8,2022 (the"Amended Term"). The definition of the word"Term"as defined in Section 1 of the Agreement is also amended to include the Amended Term. 3. Section 2, "Subscription Fee and Costs," is amended to provide that the total cost of the Subscription for the additional forty-eight(48)-month Amended Term is$49,831.20,billed to Customer as follows: forty- eight(48)invoices for monthly installment payments of$1,038.15. 4. As Customer desires to change the Equipment provided by Company during the Initial Term, Schedule B will be replaced by the attached Schedule B. During the Amended Term, Company will provide to Customer the Equipment identified on the attached amended Schedule B. 5. Section 6 is replaced with the following: 6. Termination. Either Party may terminate this Agreement prior to its expiration by giving thirty (30) days' prior written notice to the other Party upon the occurrence of any of the following events: (i)the other Party becomes insolvent, or institutes (or there is instituted against it) proceedings in bankruptcy, insolvency, reorganization or dissolution, makes an assignment for the benefit of creditors, becomes nationalized,or has any of its material assets confiscated or expropriated;(ii)except assignments permitted under the Agreement, the other Party attempts to sell, assign, delegate or transfer any of its rights and obligations under this Agreement or is dissolved, substantially changes its line of business, or sells substantially all of its assets;and/or(iii)the other Party commits a material breach of this Agreement and fails to remedy it within a reasonable period of time. 8. All other terms and conditions of the Agreement shall remain unchanged and in full force and effect except where modified by this Agreement of Amendment. The parties hereto have executed this Agreement of Ame ment,effsdi -eft ida and...yea First above written. r INDUS AL SCI I ' ' I RATION QTY OF AWATX s,Z. • By: r' '`` s �L LW— ` Name: EIARti� '54111Die QY 15. Title: V- P. COSIbMlfi OPERATIONS tONJ Title: g, ` • s S "I- r L�ao.i ¢L B , I ..,,,a."-. ��1'/G • i i a Agmt of Amendment Renewal/Equipment Change(Rev.07-06-2011) City of Augusta Case#20180319-1411878 RENEWAL EQUIPMENT CHANGES Company will ship: Qty Part Number Description 6 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord Equipment that is already onsite and will remain onsite: Qty Part Number Description 12 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger, Pump,High-Visibility Orange,UL/CSA,Soft Case,English 6 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 6 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Customer will return: Qty Part Number Description -6 18108918 iNet DS Docking Station for Ventis MX4,2 iGas Readers,Universal power cord Agmt of Amendment Renewal/Equipment Change(Rev.07-06-2011) City of Augusta Case#20180319-1411878 AMENDED SCHEDULE B EQUIPMENT SCHEDULE Total Equipment Qty Part Number Description 12 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger,Pump,High-Visibility Orange,UL/CSA,Soft Case,English 6 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 6 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 6 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Agmt of Amendment Renewal/Equipment Change(Rev.07-06-2011) City of Augusta Case#20180319-1411878 BREAKDOWN BY EQUIPMENT GROUPS Location 1:Ft Gordon Plant Qty Part Number Description 2 VTS-K1 232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger,Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Location 2:Construction Facility Qty Part Number Description 2 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger,Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Location 3:Hicks Water Treatment Plant Qty Part Number Description 2 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger, Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Location 4:Griffith Water Treatment Plant Qty Part Number Description 2 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger, Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Location 5:Maintenance Facility Qty Part Number Description 2 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger,Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders) Location 6:Metering Division Qty Part Number Description 2 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO,H2S,02,Lithium-ion Extended Range Battery,Desktop Charger,Pump,High-Visibility Orange,UL/CSA,Soft Case,English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis,3 Inlet Ports,2 iGas Readers,North America Power Cord 1 18105841 iGas Regulator w/Pressure Switch for 58,103,116L Cylinders Agmt of Amendment Renewal/Equipment Change(Rev.07-06-2011) City of Augusta Case#20180319-1411878 1 17124348 Wall/Desk Mount Cylinder Holder(for use with,34L,58L,103L,116L and 552L cylinders)