HomeMy WebLinkAboutORD 7393 TO AMEND A PORTION OF SECTION 301 OF THE SITE PLAN REGUJLATIONS DELETING ARTICLE 11 SUJBSECTION 202-EORDINANCE NO. 3 g 3
A resolution by the Augusta - Richmond County Planning Commission recommending that the
Site Plan Regulations be amended as follows:
AN ORDINANCE TO AMEND A PORTION OF SECTION 301 OF THE SITE PLAN
REGULATIONS, ADOPTED BY THE AUGUSTA COMMISSION ON OCTOBER 20,
1998 PERTAINING TO WETLAND IDEMNIFICATION
THE AUGUSTA COMMISSION HEREBY ORDAINS:
SECTION I. That the Ordinance regulating site plans in Augusta, Georgia, is amended by
deleting Article II Subsection 202 -E:
E. Eleven (11) complete sets Site Plan shall be filed with the Augusta Planning &
Development Department at the time of application. The Augusta Planning &
Development Department shall thereafter forward for review such copies as
follows:
1. One (1) copies shall be filed with Engineering Department.
2. Four (4) copies shall be filed with the Augusta Utilities Department if the
subdivision is to be served with public water and/or sewer.
3. One (1) copy shall be filed with the Traffic Engineer.
4. One (1) copy shall be filed with the Fire Department.
5. One (1) copy shall be filed with the Soil Conservation Service.
6. One (1) copy shall be filed with the Board of Health.
7. One (1) copy shall be filed with the Trees and Landscape Department.
8. One (1) copy shall be retained by the Planning Commission.
Seven (7) copies shall be submitted once the Site plan has been reviewed and
approved and the Site Plan shall be stamped in accordance with the approval of
the Augusta Planning & Development Department, and the copies shall be
distributed as follows:
1. Two (2) copies shall be returned to the applicant at the Pre - Construction
conference
2. Three (3) copies shall be retained by the Engineering Department
3. One (1) copy shall be submitted to the NPDES Inspector for inspections
purposes
4. One (1) copy shall be retained by the Augusta Planning & Development
Department
SECTION II. That the Ordinance regulating the development of land in Augusta, Georgia, is
amended by adding a new Article II Subsection 202 -E:
An electronic dwg file must be submitted to the Information Technology
Department GIS Division (IT -GIS) for review and approval per the Electronic
Submittal Process available online. The dwg will be returned to the submitter
once the road names have been approved and the addresses have been added to
the Master Address Database. This file should be the official dwg file and future
submittals and changes will need to be incorporated into the original submitted
electronic dwg file. The submitter should not submit any plan documents to the
Planning Commission until IT -GIS has approved the positional accuracy and
addressing / road naming characteristics of the plan.
F. Eleven (11) complete sets of the Site Plan and one complete electronic PDF file
shall be filed with the Planning Commission at the time of application. The
Planning Commission shall thereafter forward for review such copies as follows:
1. One (1) copies shall be filed with Engineering Department.
2. Four (4) copies shall be filed with the Utilities Department if the
subdivision is to be served with public water and/or sewer.
3. One (1) copy shall be filed with the Traffic Engineer.
4. One (1) copy shall be filed with the Fire Department.
5. One (1) copy shall be filed with the Soil Conservation Service.
6. One (1) copy shall be filed with the Board of Health.
7. One (1) copy shall be filed with the Trees and Landscape Department.
8. One (1) copy shall be retained by the Planning Commission.
Seven (7) copies and one complete electronic PDF file shall be submitted once the
Site plan has been reviewed and approved and the Site Plan shall be stamped in
accordance with the approval of the Planning Commission, and the copies shall be
distributed as follows:
5. Two (2) copies shall be returned to the applicant at the Pre - Construction
Conference
6. Three (3) copies shall be retained by the Engineering Department
7. One (1) copy shall be submitted to the NPDES Inspector for inspections
Purposes
8. One (1) copy shall be retained by the Planning Commission
A Final version of the site plan dwg and a complete electronic PDF file must be
submitted to the IT Department GIS Division per the Electronic Submittal Process
available online The dwg must include all data for integration into Augusta's
Enterprise Geodatabase, per Augusta IT -GIS Digital Data Submission Standards.
Final versions will be compared to the As -built submitted to Utilities and
variations to the Final Plat will be sent to the appropriate department to be
addressed.
SECTION III. That the Ordinance regulating site plans in Augusta, Georgia, is amended by
deleting Article III Subsection 300:
Section 300. Size and Scale of Drawings. Site Plans shall be drawn to scale no smaller than
one inch equals 100 feet. Where large sites are being planned, they may be drawn on one
or more sheets. No drawing shall exceed 36 inches by 48 inches in size.
SECTION IV. That the Ordinance regulating the development of land in Augusta, Georgia, is
amended by adding a new Article III Subsection 300:
Section 300. Size and Scale of Drawings. Site Plans shall be drawn to scale no smaller than
one inch equals 100 feet. Where large sites are being planned, they may be drawn on one or
more sheets. No drawing shall exceed 36 inches by 48 inches in size.
Format of Digital Submission: Refer to the Augusta IT -GIS Digital Data Submission
Standards and checklist for submitting the FINAL dwg file to the IT -GIS Addressing
Specialist.
SECTION IV. That the Ordinance regulating site plans in Augusta, Georgia, is amended by
deleting a portion of Article III Subsection 301 as follows:
Section 301. Information to be Included. The following information shall be included on each
Site Plan.
• Name of development, type of business, building square footage and parking
required and parking provided.
• Owner (name, address, and telephone number).
• Developer (name, address and telephone number).
• Date of survey, date plan drawn, and revision dates as applicable.
• Seal and signature of a registered engineer.
• North arrow with reference.
• Scale (no less than 1" = 100')
• Tax parcel number
• Zoning classification
• Use and zoning of all adjacent parcels with owner(s) name(s)
• Location of proposed business signage
• Existing and proposed elevations referenced to mean sea level, with a contour interval
of 2 feet, accurate to one -half contour to indicate surface drainage patterns.
• Source of datum (benchmark used: GS benchmark, if available), and location of BM or
TBM at the site.
• Existing and proposed pavement width and right -of -way width of any existing streets
adjacent to the development and distances to nearest intersection.
• Acreage of property and acreage of area to be developed.
• Location sketch (scale no less than 1" = 2000').
• All boundaries heavily lined with bearings and distances shown, accurate reference to
Augusta and/or geodetic control points which are defined by state plane coordinates
unless the sum of the length of the lines constituting the boundary of the site is greater
than the traverse distance along public roads to such control. If such reference is not
furnished, then a locator tie, defined as a bearing and distance tie from a property corner
to a point that can be accurately spotted on the ortho photo maps shall be furnished.
SECTION VI. That the Ordinance regulating the development of land in Augusta, Georgia, is
amended by amending a portion of Article III Subsection 301 as follows:
Section 301. Information to be Included. The following information shall be included on each
Site Plan.
ATTEST:
.CLERK
• Name of development, type of business, building square footage and parking
required and parking provided.
• Owner (name, address, and telephone number).
• Developer (name, address and telephone number).
• Date of survey, date plan drawn, and revision dates as applicable.
• Seal and signature of a registered engineer.
• North arrow with reference.
• Scale (no less than 1" = 100')
• Property PIN number in proper 14 digit format (Example: 047 -1- 259 -00 -0)
• Zoning classification
• Use and zoning of all adjacent parcels with owner(s) name(s)
• Location of proposed business signage
• Existing and proposed elevations referenced to mean sea level, with a contour interval
of 2 feet, accurate to one -half contour to indicate surface drainage patterns.
• Source of datum (benchmark used: GS benchmark, if available), and location of BM
and GPS point in GA State Plan Coordinates or TBM at the site.
• Existing and proposed pavement width and right -of -way width of any existing streets
adjacent to the development and distances to nearest intersection.
• Acreage of property and acreage of area to be developed.
• Location sketch (scale no less than 1" = 2000').
• All boundaries heavily lined with bearings and distances shown, accurate reference to
Augusta and/or GPS geodetic control points which are defined by state plane
coordinates unless the sum of the length of the lines constituting the boundary of the
site is greater than the traverse distance along public roads to such control. If such
reference is not furnished, then a locator tie, defined as a bearing and distance tie from a
property corner to a point that can be accurately spotted on the ortho photo maps shall
be furnished.
SECTION VII. All Ordinances or parts of Ordinances in conflict with this Ordinance are hereby
repealed.
Done in Open Meeting under the Common Seal thereof this 2 day of
April , 2013.
APPROVED THIS 2
1st reading March 19, 2013
OV
COMMISSION
day of April
/7)ocz,044
, 2013.
„..„,..(/
MAYOR, AUGUSTA COMMISSION
,"/ AUGUSTA, GEORGIA
0713