Loading...
HomeMy WebLinkAboutCHANGE ORDER #12 MCKNIGHT CONSTRUCTION WEBSTER DETENTION $12,939.06 Contractor: McKnight Construction 635 NW Frontage Road Augusta/GA/30907 Additions and Renovations to the Webster Detention Center Reference: COP# 35/43, 36, 37, 38, 39/46,41/45,44, 47 Project Description: Description of Change Miscellaneous minor mechanical/electrical design coordination deficiencies; new electric water coooler (drinking to the Scope of Work: fountain) for Video Visit Bldg; field modication of secure hollow metal frames Project Duration: Number of Days added to the Substantial Completion Date as a result of this Change to the Scope of Work: 10 Days Contract Amount Original Contract Amount Previous Change Orders Previous Contract Amount Amount of this Change Order Current Contract Amount $ 27,041,000.00 $ 6,369,124.87 $ 33,410,124.87 $ 12,939.06 $ 33,423,063.93 All terms and conditions of the Contract Agreement between the Owner and the Contractor apply to this Change Order. Signatures: Agreed to~ ~' Pat Patrick' Project Manager \D/(~101 Date to. 22 .tJL Date Recommended for Acceptance by Project Manager: NO~'dRep ~.t6. 01 Date Recommended for Acceptance by Program Manager: /!:,~~~ Bob Munger, Program Manager /6 /'''/fJ 1 Date ' i Recommended for Acceptance by The Owner: ~y / O~2/ztl9f Date ' I Captain Chester Huffman WDC Jail Administrator n ~_ _ Assistant ARC Administrator ~ Date Page 1 of 1 HEERY Cost Event Project [0400101 - Task 07] - ARC - Task 07 - Webster Detention Center View Date 10/15/2009 Heery International Inc. (Augusta, GA) 501 Greene Street Suite 307 Augusta, GA 30901 Phone: (706) 842-5543 Fax: (706) 821-2484 Cost Event No. 017 Date Type Description 10/14/2009 Budget Status Approved Design Deficiency/Omission Cost Status Pending Misc design coordination deficiencies, including CCR's 41/45, 35/43, 38, 44, 46, 47 Responsible Initiated By Pat Patrick McKnight Construction Company 645 Frontage Road NW P.O. Box 204718, 30907 Augusta, GA 30907 Phone: (706) 863-7784 Fax: (706) 863-2031 Funded By Initial Estimate Expected Final $12,936.96 (10.00 days) Long Description Misc design coordination deficiencies, including CCR's: 41/45 - Power to motorized/interlocked SEF damper 35/43 - Add butterfly control valves and BAS controls 39/46 - Power to HVAC control panels 38 - Credit for revisions to security bars at window frames 44 - Add electric water cooler (drinking fountain) at Video Visitation 47 - Drain lines for cooling towers 36/37 - Field modifications to pre-fabricated, secure hollow metal frames Items 4 6011110 Pat Patrick (McKnight Construction Company) 6011110 Pat Patrick (McKnight Construction Company) 6011110 Pat Patrick (McKnight Construction Company) Add Electric Water Cooler to Vid Viz Grade 3 Security Bars at Clerestory Storefront Windows Add Butterfly Control Valve CCR 35 120V Power for HVAC Control Panels Power to Motorized MUA Dampers interlocked with SEF's $3,000.00 $9,638.00 $6,453.00 $6,453.00 Committed Budget Cost Status Status Approved Pending No. Budget Code 6011110 Contact Description Estimated Proposed Submitted Approved Pat Patrick (McKnight Construction Company) 6011110 Pat Patrick (McKnight Construction Company) - ($21,747.00) ($21,747.00) ($21,747.00) - Approved Pending 2 3 $3,915.36 $3,915.36 $3,915.36 - Approved Pending $5,476.82 $5,282.80 $5,282.80 - Approved Pending 5 $1,356.34 $1,299.93 $1,299.93 - Approved Pending 6 6011110 Pat Patrick (McKnight Utility $9,000.00 $7,827.18 $7,827.18 $7,827.18 - Approved Pending Construction Connections Company) for Cooling Tpwers 7 6011110 Pat Patrick (McKnight Field $23,184.79 $9,907.79 - Approved Pending Construction Modification of Company) SHM Frames Estimated Proposed Submitted Approved Committed Items $12,000.00 $6,466.70 $26,216.06 $12,939.06 Markups Total $12,000.00 $6,466.70 $26,216.06 $12,939.06